Select a calculator above to begin your design or verification work.
Clean Agent / Gas Suppression System Calculator
Calculates required agent quantity (e.g., FM-200, NOVEC 1230) based on room size, temperature, and design concentration (NFPA 2001).
Water Mist System Calculator
Estimates basic water demand for initial system sizing based on hazard area and density requirements.
Foam System Calculator (NFPA 11)
Calculates the required foam concentrate volume for a spill fire based on application standards.
CO₂ System Calculator
Calculates the minimum CO₂ required for total flooding based on room volume and hazard.
Smoke Detector Spacing Calculator (NFPA 72)
Calculates maximum allowable spacing for spot-type smoke detectors based on ceiling characteristics (NFPA 72, Table 17.5.3.2.1).
Battery Standby Calculator (NFPA 72)
Determines the minimum required Amp-hour (Ah) rating for fire alarm backup batteries.
Voltage Drop Calculator
Calculates voltage loss on a wire run to ensure notification appliances receive sufficient power.
Notification Appliance Circuit (NAC) Load Calculator
Calculates the total current load on a fire alarm circuit to prevent panel overload.
Fire Stopping Material Calculator
Estimates the volume of fire sealant/mortar required for annular space around a penetration.
Fire Door Inspection Checklist Generator (NFPA 80)
Interactive checklist to verify essential fire door components are compliant. (Non-Calculator Tool)
Fire & Smoke Damper Selection Guide
Interactive wizard to recommend the correct damper type based on location and rating requirements. (Non-Calculator Tool)
Occupant Load Calculator (NFPA 101 / IBC)
Calculates the maximum number of people allowed in a space based on floor area and use.
Egress Width Calculator (NFPA 101 / IBC)
Calculates the minimum total required width for exit doors and corridors.
Emergency Lighting Point Calculator
Estimates the distance between emergency light fixtures to meet minimum coverage requirements.
Hydrant Flow Calculator (Pitot)
Calculates available water flow (GPM) from a fire hydrant using a Pitot gauge reading.
Friction Loss Calculator (Hazen-Williams)
Calculates pressure loss due to friction in pipework.
Required Fire Flow (RFF) Calculator (NFPA 1142)
Estimates the required fire flow for a commercial/industrial building based on construction and area.
Fire Pump Sizing & Head Calculator
Calculates the required pump head (pressure) based on demand and system losses.